Agar aapke solar inverter me baar-baar error codes aa rahe hain to tension lene ki zaroorat nahi. Almost har solar inverter brand—Luminous, Microtek, Growatt, UTL, Waaree, Sungrow, GoodWe, ABB, Livguard—sabke error codes ka meaning similar hota hai.
Inverter ka kaam hota hai solar panel ki DC power ko AC me convert karna. Agar panel, battery, grid ya internal circuit me koi problem hoti hai, to inverter screen par error code dikha deta hai.
Iss blog me hum detail me dekhenge:
- Common solar inverter error codes
- Error code ka real meaning
- Kya cause hota hai
- Step-by-step solutions (ghar par fix kar sakte ho)
- Kab technician bulana chahiye
Chaliye guide start karte hain! ⚡
🔍 Solar Inverter Me Error Codes Aana Kyu Shuru Hota Hai?
Solar inverter smart technology use karta hai jo:
✔ Voltage monitor karta hai
✔ Battery charge protect karta hai
✔ Solar panel output track karta hai
✔ Grid connection ko verify karta hai
Agar koi bhi parameter safe range se bahar jaye → error code.
⚠ Most Common Solar Inverter Error Codes & Solutions
Neeche sabse common error codes ka simple explanation + easy solutions diye gaye hain.
1️⃣ Error Code: PV Over Voltage / PV High Voltage
Meaning:
Solar panel ka voltage inverter ki max capacity se zyada ho gaya.
Causes:
- Extra panels series me connect
- Wrong wiring
- Oversized solar array
- Cold weather me panel voltage spike
Solution:
✔ Solar panel Voc rating check karein
✔ Zyada panels ko series se remove karein
✔ Wiring diagram verify karein
✔ MPPT settings reset karein
2️⃣ Error Code: PV Low Voltage / PV Under Voltage
Meaning:
Solar panel ka voltage minimum limit se kam hai, inverter start nahi karega.
Causes:
- Cloudy weather
- Loose solar connector
- Panel me dust/shading
- Wrong panel configuration
Solution:
✔ MC4 connectors tight karein
✔ Wiring connection recheck karein
✔ Panel clean karein
✔ Series/paralle configuration correct karein
3️⃣ Error Code: Grid Fail / AC Input Fail
Meaning:
Inverter ko grid ka input (AC) nahi mil raha.
Causes:
- Grid outage
- MCB off
- Loose wire
- AC cable damaged
Solution:
✔ Grid supply check karein
✔ MCB on karein
✔ AC input wire tighten karein
✔ Fuse check karein
4️⃣ Error Code: Battery Low / Battery Under Voltage
Meaning:
Battery safe limit se niche discharge ho chuki hai.
Causes:
- Poor battery health
- Solar charging low
- Extra load
- Faulty battery wire
Solution:
✔ Battery ko fully charge karein
✔ Load kam karein
✔ Battery water level check karein
✔ Damaged battery wire replace karein
5️⃣ Error Code: Battery High Voltage / Over Voltage
Meaning:
Battery excessively charge ho rahi hai.
Causes:
- Charge controller issue
- Panel over wattage
- Faulty MPPT/PWM
Solution:
✔ Charge controller settings reset karein
✔ Battery terminals saaf karein
✔ MPPT/PWM check karein
✔ Oversized panel ko balance karein
6️⃣ Error Code: Overload / Load High
Meaning:
Inverter se zyada load consumption ho raha hai.
Causes:
- High power devices (AC, heater)
- Extra appliances
- Loose output wire
Solution:
✔ Load reduce karein
✔ Only suitable devices use karein
✔ Wiring heat check karein
7️⃣ Error Code: Short Circuit / Output Short
Meaning:
Inverter output side me short circuit detect hua.
Causes:
- Faulty plug
- Damaged wiring
- High-pressure device
Solution:
✔ Sab plugs inspect karein
✔ Shorted wiring replace karein
✔ Load recheck karein
8️⃣ Error Code: Isolation Resistance Fault
Meaning:
Panel wiring ya AC output me leakage current detect hua.
Causes:
- Wet wiring
- Insulation damage
- Faulty earthing
Solution:
✔ Earthing check karein
✔ Wet connectors dry karein
✔ Faulty wire change karein
9️⃣ Error Code: Temperature High / Over Temperature
Meaning:
Inverter ka internal temperature safe limit se upar hai.
Causes:
- Fan jam
- Poor air ventilation
- Heat waves
- High load
Solution:
✔ Inverter ko airy space me install karein
✔ Cooling fan clean karein
✔ Overload reduce karein
🔟 Error Code: Communication Lost / Com Error
Meaning:
Inverter aur monitoring device (WiFi dongle, app) ka connection lost ho gaya.
Causes:
- Cable loose
- WiFi failure
- App not working
Solution:
✔ WiFi dongle replug karein
✔ App restart karein
✔ RS485/USB cable reinsert karein
🔧 Additional Error Codes List (Quick Table)
| Error Code | Meaning | Quick Fix |
|---|---|---|
| E01 | Overload | Load reduce |
| E02 | Battery low | Battery charge |
| E03 | Over temperature | Cool down |
| E04 | PV error | Panel wiring check |
| E05 | Grid error | AC input check |
| E06 | Communication error | Cable/WiFi check |
| E07 | Fan failure | Fan clean/replace |
🛠 Jab Ye Errors Technician Required Hote Hain
Aapko professional technician bulana चाहिए agar:
✔ Burning smell aaye
✔ Display completely dead ho
✔ Wiring heat ho rahi ho
✔ Repeated error fix nahi ho raha
✔ Grid synchronization problem ho
💡 Conclusion
Solar inverter errors normal hote hain aur inka solution easy bhi hota hai.
Agar daily basis par sahi maintenance ho, wiring proper ho, aur system clean rahe, to inverter long-lasting performance deta hai.
❓ FAQs
Q1. Solar inverter me error code kaise reset karein?
Generally inverter off → wait 10 seconds → on.
Ya “Reset” button press karein.
Q2. Error codes dangerous hote hain?
Nahi, yeh automatic safety alerts hote hain.
Q3. PV High Voltage ka solution kya hai?
Panel configuration check karein, extra panels series se remove karein.
Q4. Battery low error baar-baar kyu aata hai?
Battery weak ho gayi ya load zyada hai.
Q5. Over temperature error ka solution kya hai?
Fan clean karein, ventilation improve karein.
Discover more from Xolargyan.com
Subscribe to get the latest posts sent to your email.