Solar System Power Output Kam Kyu Ho Raha Hai? (Troubleshooting Guide)

Jaane solar system ka output kam kyu ho raha hai aur kaise sudharen. Step-by-step troubleshooting guide in Hindi for better solar efficiency.

☀️ Introduction

Aapne ghar ya business par solar system lagaya, pehle sab sahi chal raha tha…
Par ab aap notice kar rahe ho ki solar generation kam ho gaya hai.

Output me 20–30% drop ek common problem hai — lekin tension lene ki zarurat nahi.
Is blog me hum jaanenge:
✅ Solar system ka output kam hone ke reason
✅ Kaise check karein
✅ Step-by-step solution


⚡ Chapter 1: Solar Output Kam Hone Ke Common Reasons

Solar system ka performance kai factors par depend karta hai. Yahaan sabse common 10 causes diye gaye hain:

CauseDescriptionSolution
1️⃣ Dust & DirtPanel par mitti aur bird droppings light block karte hainPanel regular saaf karein
2️⃣ Shading IssueTree, dish antenna, ya wire ki shadowPanel area shadow-free rakhein
3️⃣ Loose ConnectionWire ya MC4 connector looseElectrical check-up karayein
4️⃣ Inverter ErrorFault code aana ya trip honaManual check + service support
5️⃣ Battery Issue (Off-grid)Low voltage ya sulphationBattery water & voltage test karein
6️⃣ Low Sunlight / WeatherCloudy season me irradiance kamSeasonal variation normal hai
7️⃣ Panel AgeingEfficiency drop over yearsPanel replacement consider karein
8️⃣ Temperature RiseHigh heat = low voltageVentilation improve karein
9️⃣ Improper Tilt AngleWrong direction se sunlight lossSouth-facing angle maintain karein
🔟 MPPT/PWM FaultCharge controller malfunctionReset or replace controller

🔍 Chapter 2: Step-by-Step Troubleshooting Guide

🔹 Step 1: Visual Inspection

  • Dekhiye panel par dirt, bird droppings, ya crack to nahi.
  • Wires aur junction box tight hai ya nahi.
  • Inverter display par koi error code to nahi.

🔹 Step 2: Cleaning Test

Panel ko soft cloth aur clean water se saaf karein.
Zyada dust hone par 10–20% output loss hota hai.

🔹 Step 3: Inverter Reading Check

Inverter ka generation reading aur voltage check karein.
Agar inverter blinking light dikha raha hai → error code note karein.

🔹 Step 4: Shadow Mapping

Subah se shaam tak dekhein koi shadow to nahi pad rahi.
Ek chhoti si shadow bhi poore string ke output ko kam kar sakti hai.

🔹 Step 5: Voltage & Current Test

Multimeter se DC voltage aur current measure karein.
Ek panel me 18–22V hona chahiye (depending on wattage).

🔹 Step 6: Panel Temperature Check

High temperature me efficiency har 1°C par 0.4–0.5% girti hai.
Ensure airflow below panels.


⚙️ Chapter 3: Solar Generation Formula

Total Solar Output (Units/day) = System Size (kW) × Avg Sun Hours × Efficiency

Example:
5 kW system × 4.5 hrs × 0.8 = 18 units/day

Agar aapka output 18 se 10 unit tak gir gaya hai → 40% drop → zarur koi issue hai.


🔆 Chapter 4: How to Improve Solar Efficiency

1. Clean Regularly — Har 15 din me cleaning schedule rakhein
2. Maintain Tilt — South-facing 20–30° tilt best hai
3. Annual Service — Har saal technician se inspection
4. Monitor Performance — Smart inverter app use karein
5. Replace Faulty Panels — Crack ya micro damage panel hataayein


🔋 Chapter 5: Solar Inverter Error Codes (Example Table)

Error CodeMeaningAction
101Grid Voltage LowWait until voltage normal
201DC Over VoltageCheck PV array voltage
301Earth FaultCall technician
401Over TemperatureCooling improve karein
501Isolation FaultWire insulation test karein

🧠 Chapter 6: Preventive Maintenance Tips

1️⃣ Har 6 mahine me performance audit karayein
2️⃣ Inverter room ventilated rakhein
3️⃣ Wires par rodents se bachav karein
4️⃣ Lightning & SPD install karein
5️⃣ Solar app par daily generation track karein


🌞 Chapter 7: FAQs

Q1. Mera solar generation pehle 10 unit tha, ab 6 unit kyu ho gaya?
Dust, weather, ya inverter issue ho sakta hai. Panel cleaning aur inverter check karein.

Q2. Panel cleaning ke baad kitna improvement hota hai?
10–25% tak generation improve hota hai.

Q3. Cloudy din me output kam hona normal hai kya?
Haan, 30–40% tak drop normal hai.

Q4. Solar panel ki lifespan kitni hoti hai?
25 years tak, lekin 20 saal baad output 80% ke aaspaas hota hai.

Q5. MPPT controller kya karta hai?
Ye solar voltage aur current optimize karke battery ya inverter ko best power deta hai.


✅ Conclusion

Agar aapka solar power output kam ho raha hai, to ghabraiye nahi.
Zyada cases me issue simple maintenance ya wiring fault se solve ho jata hai.

👉 Har 15 din me panel saaf karein, inverter readings track karein aur annual service zarur karayein.

Solar system ek long-term investment hai — thoda maintenance, zyada fayda! ☀️